VCU
Interlink power cables.
VCU series are thought to facilitate the connexions between applications by directly connecting between DCM Sistemes products and connecting with other brands. These cables simplify connection schemes and avoid the excess of cables in the applications.

*Check for sizes larger than 150cm.
Models
VCU01A

Interconnect lighting systems for PLD and PLU series.
Interconnect lighting systems from PLD
and PLU, whenever we want to use
multiple devices of these series in a single application, avoiding
wiring from each device to the power source.
With VCB 2 poles female connector
on each side.


Specifications
Length* | 30cm | 50cm | 100cm | 150cm |
---|---|---|---|---|
Order reference | VCU01A003 | VCU01A005 | VCU01A010 | VCU01A015 |
*Check for sizes larger than 150cm.
Connections
2 to 2 Poles | +VCD | GND |
---|---|---|
Connector VCB 2p. female | PIN 1 | PIN 2 |
Connector VCB 2p. female | PIN 1 | PIN 2 |
VCU02A

Adapter cable from VCB (male) connector to VCC (female) connector.
It is a special cable that allows us to connect systems with 3 pin connector to 2 pin connector. This connection allows forcing the continuous mode for iBluedrive systems or for systems with control terminal without the need of an extra wiring. In this case, the control cable would be bridged with GND.
VCU03A

Adapter cable from VCC (male) connector to VCB (female) connector.
It is a converter cable from VCC 3 pin to VCB 2 pin connector. It is designed for linking led lighting systems with 2 pins in applications with DCM systems with 3 pin connector. Thus, in case you need to change the lighting system in an application, it is not necessary to change all the wiring. The Control cable in this case would be disconnected.
VCU04A

Interconnection cable between VCB female to M12 male.
It is a cable that connects VCB 2 pin female cables to M12 male. With this cable we can connect DCM systems with 2 pins in applications where M12 connections are used. For example, we can connect DCM systems directly to COGNEX cameras that have connectorl light control connection, such as the In-Sight 7000, In-Sight 9000 and the DataMan 300 allowing us to power the light in continuous mode directly from the camera.

Specifications
Length* | 30cm | 50cm | 100cm | 150cm |
---|---|---|---|---|
Order reference | VCU04A003 | VCU04A005 | VCU04A010 | VCU04A015 |
Cámaras compatibles | Cameras with connectorl light control connector: In-Sight 7000, In-Sight 9000, DataMan 300 |
*Check for sizes larger than 150cm.
Connections
3 to 2 Poles | +VDC | Ground | Control |
---|---|---|---|
Connector M12 male | PIN 1 | PIN 3 | PIN 4 |
Connector VCB 2p. female | PIN 1 | PIN 2 | Not connected |
VCU05A

Interconnection cable from VCC female to M12 male.
Connection cable between VCC 3 pin female cables to M12 male connector. With this cable we can directly connect 3 pin DCM lighting systems in applications where M12 connection is used. For example, we can link DCM systems directly to COGNEX cameras with connectorl light control connection, such as the In-Sight 7000, In-Sight 9000 and the DataMan 300 allowing us to power the light and control it directly from the camera software.

Specifications
Length* | 30cm | 50cm | 100cm | 150cm |
---|---|---|---|---|
Order reference | VCU05A003 | VCU05A005 | VCU05A010 | VCU05A015 |
Cámaras compatibles | Cameras with connectorl light control connector: In-Sight 7000, In-Sight 9000, DataMan 300 |
*Check for sizes larger than 150cm.
Connections
3 to 3 Poles | +VDC | GND | Control | (Strobe)
---|---|---|---|
Connector M12 male | PIN 1 | PIN 3 | PIN 4 |
Connector VCC 3p female. | PIN 1 | PIN 2 | PIN 3 |

Example: COGNEX DataMan 300 camera directly connected to a BKL0303A-630C system in continuous mode.
VCU06A

Interconnection cable from VCB male to VCB female(x2).
VCB Y Splitter cordset that allows to power two lights from just one cable. On one side it has an aerial male VCB connector and on the other side two aerial female VCB connectors connected in parallel. This is very useful in installations where there is only one VCB cable installed and we have two DCM Sistemes systems.
VCU07A

Interconnection cable from VCC male to VCC female(x2).
VCC Y Splitter cordset that allows to power two lights from just one cable. On one side it has an aerial male VCC connector and on the other side two aerial female VCC connectors connected in parallel. This is very useful in installations where there is only one VCC cable installed and we have two DCM Sistemes systems.

Specifications
Length* | 30cm | 50cm | 100cm | 150cm |
---|---|---|---|---|
Order reference | VCU07A003 | VCU07A005 | VCU07A010 | VCU07A015 |
*Check for sizes larger than 150cm.
Connections
3 to 3 Poles | +VDC | GND | Control |
---|---|---|---|
Connector VCC 3p male. | PIN 1 | PIN 2 | PIN 3 |
Connector VCC 3p female (x2). | PIN 1 | PIN 2 | PIN 3 |

VCU08A

Interconnection cable from VCB male to VCB female(x3).
VCB Y Splitter cordset that allows to power three lights from just one cable. On one side it has an aerial male VCB connector and on the other side three aerial female VCB connectors connected in parallel. This is very useful in installations where there is only one VCB cable installed and we have three DCM Sistemes systems.
VCU09A

Interconnection cable from VCC male to VCC female(x3).
VCC Y Splitter cordset that allows to power three lights from just one cable. On one side it has an aerial male VCC connector and on the other side three aerial female VCC connectors connected in parallel. This is very useful in installations where there is only one VCC cable installed and we have three DCM Sistemes systems.
VCU10A

Interconnection cable from VCB male to VCB female(x4).
VCB Y Splitter cordset that allows to power four lights from just one cable. On one side it has an aerial male VCB connector and on the other side four aerial female VCB connectors connected in parallel. This is very useful in installations where there is only one VCB cable installed and we have four DCM Sistemes systems.
VCU11A

Interconnection cable from VCC male to VCC female(x4).
VCC Y Splitter cordset that allows to power four lights from just one cable. On one side it has an aerial male VCC connector and on the other side four aerial female VCC connectors connected in parallel. This is very useful in installations where there is only one VCC cable installed and we have four DCM Sistemes systems.
VCU12A

Interconnection cable from VCC male to VCC female(x5).
VCC Y Splitter cordset that allows to power five lights from just one cable. On one side it has an aerial male VCC connector and on the other side five aerial female VCC connectors connected in parallel. This is very useful in installations where there is only one VCC cable installed and we have five DCM Sistemes systems.
VCU13A

Interconnection cable from VCB male to VCB female(x5).
VCB Y Splitter cordset that allows to power five lights from just one cable. On one side it has an aerial male VCB connector and on the other side five aerial female VCB connectors connected in parallel. This is very useful in installations where there is only one VCB cable installed and we have five DCM Sistemes systems.
VCU16A

Connection cable between VCC3 pin male cables to M8 female connector.
Connecting cables between 3-pin male VCC cables to M8 female connection. This cable is used to directly connect DCM lighting equipment with M8 connection to applications and installations using VCC connections.

Specificaciones
Length.* | 10cm |
---|---|
Order reference | VCU16A001 |
*Check for other lengths.
Connections
3 to 3 Poles | +VDC | GND | Control |
---|---|---|---|
Connector VCC 3p male. | PIN 1 | PIN 2 | PIN 3 |
Connector M8 female | PIN 1 | PIN 3 | PIN 4 |
Downloads
PDF technical drawing (VCU04A)
PDF technical drawing (VCU05A)
PDF technical drawing (VCU07A)
PDF technical drawing (VCU09A)
PDF technical drawing (VCU10A)
PDF technical drawing (VCU11A)
PDF technical drawing (VCU12A)
PDF technical drawing (VCU13A)
PDF technical drawing (VCU16A)
Contact

DCM Sistemes
Pol. Ind. 'El Oliveral', C/ X esquina con C/ G. 46190 - Ribarroja del Turia. Valencia (España)
Tel.:(+34) 96 166 65 27 | Fax: (+34) 96 166 65 24
info@dcmsistemes.com | www.dcmsistemes.com
Link: https://www.dcmsistemes.com/en/products/accessories/vcu/