Page 1

VCC

3 poles power cable with free terminals

For series: ALB, AMS, AUB, DOL, PLA, PLC, PRC, PRF, PRH, SAR and iBlueDrive devices.

* Except DOLnnn0C

VCC

Specifications

No. Poles 3
Section 2 x 0.5mm2 + 1 x 0,20mm2
Connector Normal or angled connector
Conductor Flexible and polished coopper s/UNE-EN 13602
Isolation Composed of PVC type TI52 s/EN 50290-2-21
Mechanical part PVC black color type TM51
Nominal voltage C.A. ≤250V
Nominal voltage C.C. ≤300V
Test voltage 1000V
Temperature -15ºC a +70ºC
Security No fire propagator s/UNE-EN 60332-1-2
Resistance 0,50mm2 39mΩ/m conductor*
Resistance 0,20mm2 108mΩ/m conductor**
Maximum current 30ºC 5Amp.
External diameter 4,9±0,15mm
Minimum bend radius 25mm @ 20±10ºC ambient temperature

*Conductor meters by which current flows are usually twice the length of the cable since current goes by the positive conductor and comes back by ground conductor. So, a resistance of 78mΩ/m will be present.
** In this case a resitance of 216Ω/m will be present


Connection according to type of lamp  (+)

Colour Type C Type P Type S Type i
PIN 1 RD +VDC +VDC OUT (+) +VDC
PIN 2 BU / BK GND 1 (-) GND 1 (-) OUT 1 (-) GND
PIN 3

bichromatic lamps monochromatic lamps with control

GN GND 2 (-)
CONTROL
GND 2 (-)
CONTROL
OUT 2 (-)
CONTROL
CONTROL

Order reference

The order reference for a cable with normal connector is composed of model and lenght. In case of ordering a cable with right angle connector (optional), please add its code at the end.

Model

VCC

Cable length (m) *

018



* Consult for other measures

Modifier (optional)

-


-AC1 = Front angled connector
Outputs the cable in the same direction as the bias mark of the device’s male chassis connector.

-AC2 = Rear angled connector
Outputs the cable in the opposite direction of the bias mark of the device’s male chassis connector.

/FX = Flexible cable
Flexible cable for cable carrier chains

Example: VCC 018: Cable of 1.8m length with normal connector
VCC018-AC1: Cable of 1.8m length with right angle connector that outputs the cable to the opposite direction as the bias point of the male chassis connector.

Main Dimensions

Plano de VCC

Cable diagram with right angle connector (two options available):

Plano de VCC

*Dimensions referred to a plugged cable. Tolerance class in accordance with ISO 2678 medium.